Find a nursing homeFind a home

Home / F-tags / F906

F906: Provide enough power supply for lighting all entrances and exits; equipment for fire detection and alarm systems, and extinguishers

CMS category: environmental · All F-tags

11citations in the CMS files
11homes cited at least once
2in the 12 months to September 2026
9.1%rated actual harm or immediate jeopardy

CMS Health Deficiencies file, data as of September 1, 2026. The files hold each home's last three standard inspections and three years of complaint visits.

How seriously inspectors rate it

Mostly not at the harm level: 90.9% were D, E or F (potential for more than minimal harm) and 1 reached actual harm or worse.

Immediate jeopardy (J, K, L)
1 (9.1%)
Actual harm (G, H, I)
0 (0.0%)
Potential for more than minimal harm (D, E, F)
10 (90.9%)
Potential for minimal harm (A, B, C)
0 (0.0%)
From complaint visits
4 (36.4%)

By letter: D 4, E 2, F 4, J 1.

What inspectors wrote

Quoted from the inspectors' statements of deficiencies (CMS form 2567); CMS removes names.

Inspectors wrote · February 25, 2026 · scope and severity FBased on interview and record review, the facility experienced a power failure related to an area wide power outage. The facility's backup generator failed to provide back up power for the facility as it is designed to do during a power outage. The facility failed to ensure the safety of all residents dependent on life-sustaining equipment related to inability to provide electricity to life sustaining devices during the power failure. The facility failed to document the generator was in working order by completed weekly testing and monthly testing under load to ensure the backup generators availability in an emergency.

Elevate Care Des Plaines, Des Plaines, IL

Inspectors wrote · June 11, 2025 · scope and severity DBased on record review, observation, and interviews it was determined that the facility failed to ensure that critical medical equipment was plugged into generator power supplied outlets. This was evident for one (Resident #102) out of two residents reviewed for respiratory care.

Autumn Lake Healthcare at Birch Manor, Sykesville, MD

Inspectors wrote · May 22, 2025 · scope and severity FBased on interview and record review, the facility failed to maintain an operable emergency electrical power system to ensure electrical power to life support systems in the event of a power outage, effecting all 82 residents in the facility.

The Villa at the Bay, Petoskey, MI

Most recent F906 citations at the harm or jeopardy level

Newest first, all 1; each home's page shows the citation and its correction status.

InspectionHomeTownLetterVisit
November 14, 2023Bridge Crest Post AcuteVancouver, WA JStandard

Most recent F906 citations

InspectionHomeTownLetter
April 24, 2026Casa Coloma Health Care CenterRancho Cordova, CA D
February 25, 2026Elevate Care Des PlainesDes Plaines, IL F
June 11, 2025Autumn Lake Healthcare at Birch ManorSykesville, MD D
May 22, 2025The Villa at the BayPetoskey, MI F
December 27, 2024Tulare Healthcare & Wellness Center, LPTulare, CA E
July 23, 2024Arbor Care Center-Valhaven, LLCValley, NE F
July 17, 2024Life Care Center of TucsonTucson, AZ E
July 2, 2024Berkley East Healthcare CenterSanta Monica, CA D
January 23, 2024Noble Care CenterStockton, CA D
November 14, 2023Bridge Crest Post AcuteVancouver, WA J
August 5, 2022Butler Rehab and Healthcare CenterButler, MO F

F906 citations by state

A count reflects how many homes a state has and how often it inspects, not only its record.

By inspection year: 2022 1, 2023 1, 2024 5, 2025 2, 2026 2.

  • Citations: CMS Health Deficiencies, released September 30, 2026, data as of September 1, 2026.
  • Inspectors' guidance for each F-tag: CMS State Operations Manual, Appendix PP.
  • NursingHomeClear reports citations as CMS records them and is not affiliated with CMS. Methodology